Main Menu (Mobile)- Block

Main Menu - Block

janelia7_blocks-janelia7_fake_breadcrumb | block
Gonen Lab / Publications
general_search_page-panel_pane_1 | views_panes

91 Publications

Showing 31-40 of 91 results
Gonen Lab
07/01/08 | Electron crystallography of aquaporins.
Andrews S, Reichow SL, Gonen T
IUBMB Life. 2008 Jul;60(7):430-6. doi: 10.1002/iub.53

Aquaporins are a family of ubiquitous membrane proteins that form a pore for the permeation of water. Both electron and X-ray crystallography played major roles in determining the atomic structures of a number of aquaporins. This review focuses on electron crystallography, and its contribution to the field of aquaporin biology. We briefly discuss electron crystallography and the two-dimensional crystallization process. We describe features of aquaporins common to both electron and X-ray crystallographic structures; as well as some structural insights unique to electron crystallography, including aquaporin junction formation and lipid-protein interactions.

View Publication Page
Gonen Lab
07/13/11 | Fragment-based phase extension for three-dimensional structure determination of membrane proteins by electron crystallography.
Wisedchaisri G, Gonen T
Structure. 2011 Jul 13;19:976-87. doi: 10.1016/j.str.2011.04.008

In electron crystallography, membrane protein structure is determined from two-dimensional crystals where the protein is embedded in a membrane. Once large and well-ordered 2D crystals are grown, one of the bottlenecks in electron crystallography is the collection of image data to directly provide experimental phases to high resolution. Here, we describe an approach to bypass this bottleneck, eliminating the need for high-resolution imaging. We use the strengths of electron crystallography in rapidly obtaining accurate experimental phase information from low-resolution images and accurate high-resolution amplitude information from electron diffraction. The low-resolution experimental phases were used for the placement of α helix fragments and extended to high resolution using phases from the fragments. Phases were further improved by density modifications followed by fragment expansion and structure refinement against the high-resolution diffraction data. Using this approach, structures of three membrane proteins were determined rapidly and accurately to atomic resolution without high-resolution image data.

View Publication Page
Gonen Lab
03/01/18 | From electron crystallography of 2D crystals to MicroED of 3D crystals.
Martynowycz MW, Gonen T
Current Opinion in Colloid & Interface Science . 2018 Mar;34:9-16. doi: 10.1016/j.cocis.2018.01.010

Electron crystallography is widespread in material science applications, but for biological samples its use has been restricted to a handful of examples where two-dimensional (2D) crystals or helical samples were studied either by electron diffraction and/or imaging. Electron crystallography in cryoEM, was developed in the mid-1970s and used to solve the structure of several membrane proteins and some soluble proteins. In 2013, a new method for cryoEM was unveiled and named Micro-crystal Electron Diffraction, or MicroED, which is essentially three-dimensional (3D) electron crystallography of microscopic crystals. This method uses truly 3D crystals, that are about a billion times smaller than those typically used for X-ray crystallography, for electron diffraction studies. There are several important differences and some similarities between electron crystallography of 2D crystals and MicroED. In this review, we describe the development of these techniques, their similarities and differences, and offer our opinion of future directions in both fields.

View Publication Page
Gonen Lab
01/01/00 | Galectin-3 is associated with the plasma membrane of lens fiber cells.
Gonen T, Donaldson P, Kistler J
Investigative Ophthalmology & Visual Science. 2000 Jan;41(1):199-203

PURPOSE: To discover proteins that have the potential to contribute to the tight packing of fiber cells in the lens.

METHODS: Crude fiber cell membranes were isolated from ovine lens cortex. Proteins were separated by two-dimensional gel electrophoresis, and selected protein spots identified by micro-sequencing. The identification of galectin-3 was confirmed by immunoblotting with a specific antibody. The association of galectin-3 with the fiber cell plasma membrane was investigated using immunofluorescence microscopy, solubilization trials with selected reagents, and immunoprecipitation to identify candidate ligands.

RESULTS: A cluster of three protein spots with an apparent molecular weight of 31,000 and isoelectric points ranging between 7 and 8.5 were resolved and identified as galectin-3. This protein was associated peripherally with the fiber cell plasma membrane and interacted with MP20, an abundant intrinsic membrane protein that had been identified previously as a component of membrane junctions between fiber cells.

CONCLUSIONS: The detection of galectin-3 in the lens is a novel result and adds to the growing list of lens proteins with adhesive properties. Its location at the fiber cell membrane and its association with the junction-forming MP20 is consistent with a potential role in the development or maintenance of the tightly packed lens tissue architecture.

View Publication Page
Gonen Lab
09/12/13 | Haemolysin coregulated protein is an exported receptor and chaperone of type VI secretion substrates.
Silverman JM, Agnello DM, Zheng H, Andrews BT, Li M, Catalano CE, Gonen T, Mougous JD
Molecular Cell. 2013 Sep 12;51(5):584-93. doi: 10.1016/j.molcel.2013.07.025

Secretion systems require high-fidelity mechanisms to discriminate substrates among the vast cytoplasmic pool of proteins. Factors mediating substrate recognition by the type VI secretion system (T6SS) of Gram-negative bacteria, a widespread pathway that translocates effector proteins into target bacterial cells, have not been defined. We report that haemolysin coregulated protein (Hcp), a ring-shaped hexamer secreted by all characterized T6SSs, binds specifically to cognate effector molecules. Electron microscopy analysis of an Hcp-effector complex from Pseudomonas aeruginosa revealed the effector bound to the inner surface of Hcp. Further studies demonstrated that interaction with the Hcp pore is a general requirement for secretion of diverse effectors encompassing several enzymatic classes. Though previous models depict Hcp as a static conduit, our data indicate it is a chaperone and receptor of substrates. These unique functions of a secreted protein highlight fundamental differences between the export mechanism of T6 and other characterized secretory pathways.

View Publication Page
Gonen Lab
02/01/13 | HCV IRES manipulates the ribosome to promote the switch from translation initiation to elongation.
Filbin ME, Vollmar BS, Shi D, Gonen T, Kieft JS
Nature Structural & Molecular Biology. 2013 Feb;20(2):150-8. doi: 10.1038/nsmb.2465

The internal ribosome entry site (IRES) of the hepatitis C virus (HCV) drives noncanonical initiation of protein synthesis necessary for viral replication. Functional studies of the HCV IRES have focused on 80S ribosome formation but have not explored its role after the 80S ribosome is poised at the start codon. Here, we report that mutations of an IRES domain that docks in the 40S subunit’s decoding groove cause only a local perturbation in IRES structure and result in conformational changes in the IRES-rabbit 40S subunit complex. Functionally, the mutations decrease IRES activity by inhibiting the first ribosomal translocation event, and modeling results suggest that this effect occurs through an interaction with a single ribosomal protein. The ability of the HCV IRES to manipulate the ribosome provides insight into how the ribosome’s structure and function can be altered by bound RNAs, including those derived from cellular invaders.

View Publication Page
Gonen Lab
10/24/14 | High thermodynamic stability of parametrically designed helical bundles.
Huang P, Oberdorfer G, Xu C, Pei XY, Nannenga BL, Rogers JM, DiMaio F, Gonen T, Luisi B, Baker D
Science. 2014 Oct 24;346(6208):481-5. doi: 10.1126/science.1257481

We describe a procedure for designing proteins with backbones produced by varying the parameters in the Crick coiled coil-generating equations. Combinatorial design calculations identify low-energy sequences for alternative helix supercoil arrangements, and the helices in the lowest-energy arrangements are connected by loop building. We design an antiparallel monomeric untwisted three-helix bundle with 80-residue helices, an antiparallel monomeric right-handed four-helix bundle, and a pentameric parallel left-handed five-helix bundle. The designed proteins are extremely stable (extrapolated ΔGfold > 60 kilocalories per mole), and their crystal structures are close to those of the design models with nearly identical core packing between the helices. The approach enables the custom design of hyperstable proteins with fine-tuned geometries for a wide range of applications.

View Publication Page
Gonen Lab
01/01/13 | High throughput methods for electron crystallography.
Stoke D, Ubarretxena-Belandia I, Gonen T, Engel A
Methods in Molecular Biology. 2013;955:273-96. doi: 10.1007/978-1-62703-176-9_15

Membrane proteins play a tremendously important role in cell physiology and serve as a target for an increasing number of drugs. Structural information is key to understanding their function and for developing new strategies for combating disease. However, the complex physical chemistry associated with membrane proteins has made them more difficult to study than their soluble cousins. Electron crystallography has historically been a successful method for solving membrane protein structures and has the advantage of providing a native lipid environment for these proteins. Specifically, when membrane proteins form two-dimensional arrays within a lipid bilayer, electron microscopy can be used to collect images and diffraction and the corresponding data can be combined to produce a three-dimensional reconstruction, which under favorable conditions can extend to atomic resolution. Like X-ray crystallography, the quality of the structures are very much dependent on the order and size of the crystals. However, unlike X-ray crystallography, high-throughput methods for screening crystallization trials for electron crystallography are not in general use. In this chapter, we describe two alternative methods for high-throughput screening of membrane protein crystallization within the lipid bilayer. The first method relies on the conventional use of dialysis for removing detergent and thus reconstituting the bilayer; an array of dialysis wells in the standard 96-well format allows the use of a liquid-handling robot and greatly increases throughput. The second method relies on titration of cyclodextrin as a chelating agent for detergent; a specialized pipetting robot has been designed not only to add cyclodextrin in a systematic way, but to use light scattering to monitor the reconstitution process. In addition, the use of liquid-handling robots for making negatively stained grids and methods for automatically imaging samples in the electron microscope are described.

View Publication Page
Gonen Lab
06/16/16 | High-resolution macromolecular structure determination by MicroED, a cryo-EM method.
Rodriguez JA, Gonen T
Methods in Enzymology. 2016 Jun 16:. doi: 10.1016/bs.mie.2016.04.017

Microelectron diffraction (MicroED) is a new cryo-electron microscopy (cryo-EM) method capable of determining macromolecular structures at atomic resolution from vanishingly small 3D crystals. MicroED promises to solve atomic resolution structures from even the tiniest of crystals, less than a few hundred nanometers thick. MicroED complements frontier advances in crystallography and represents part of the rebirth of cryo-EM that is making macromolecular structure determination more accessible for all. Here we review the concept and practice of MicroED, for both the electron microscopist and crystallographer. Where other reviews have addressed specific details of the technique (Hattne et al., 2015Shi et al., 2016 and Shi et al., 2013), we aim to provide context and highlight important features that should be considered when performing a MicroED experiment.

View Publication Page
Gonen Lab
09/01/14 | High-resolution structure determination by continuous-rotation data collection in MicroED.
Nannenga BL, Shi D, Leslie AG, Gonen T
Nature Methods. 2014 Sep;11(9):927-30. doi: 10.1038/nmeth.3043

MicroED uses very small three-dimensional protein crystals and electron diffraction for structure determination. We present an improved data collection protocol for MicroED called 'continuous rotation'. Microcrystals are continuously rotated during data collection, yielding more accurate data. The method enables data processing with the crystallographic software tool MOSFLM, which resulted in improved resolution for the model protein lysozyme. These improvements are paving the way for the broad implementation and application of MicroED in structural biology.

View Publication Page