Main Menu (Mobile)- Block
- Overview
-
Support Teams
- Overview
- Anatomy and Histology
- Cryo-Electron Microscopy
- Electron Microscopy
- Flow Cytometry
- Gene Targeting and Transgenics
- Immortalized Cell Line Culture
- Integrative Imaging
- Invertebrate Shared Resource
- Janelia Experimental Technology
- Mass Spectrometry
- Media Prep
- Molecular Genomics
- Primary & iPS Cell Culture
- Project Pipeline Support
- Project Technical Resources
- Quantitative Genomics
- Scientific Computing Software
- Scientific Computing Systems
- Viral Tools
- Vivarium
- Open Science
- You + Janelia
- About Us
Main Menu - Block
- Overview
- Anatomy and Histology
- Cryo-Electron Microscopy
- Electron Microscopy
- Flow Cytometry
- Gene Targeting and Transgenics
- Immortalized Cell Line Culture
- Integrative Imaging
- Invertebrate Shared Resource
- Janelia Experimental Technology
- Mass Spectrometry
- Media Prep
- Molecular Genomics
- Primary & iPS Cell Culture
- Project Pipeline Support
- Project Technical Resources
- Quantitative Genomics
- Scientific Computing Software
- Scientific Computing Systems
- Viral Tools
- Vivarium
MIMMS 1.0 (2016)
Modular In vivo Multiphoton Microscopy System (MIMMS)
MIMMS (Modular In vivo Multiphoton Microscopy System) is a modular platform for performing two‐photon laser scanning microscopy (TPLSM) optimized for in vivo applications. The system generally uses commercially available core parts for movement of the objective in the X‐, Y‐, and Z‐axis linear translation and X‐axis rotation for in vivo experiments. The backbone of the design is a movable, raised optical breadboard, providing a large area for affixing optical equipment associated with the microscope. The raised design also provides space for additional testing equipment and allows the entire microscope system to be moved out of the way for 360° access to the working area. The microscope is designed with a modular approach to the components, with interchangeable systems for different laser scanning modalities, moving and fixed objective lens mounting, widefield conventional imaging, and high acceptance, non-descanned fluorescence detection.
Advantages:
- The design allows for an extensible in vivo 2-photon microscopy system
- The system provides suitable clearance for additional apparatus needed for the specimen.
- MIMMS can be completely moved out of the way to permit full 360° access to the specimen.
- Design created to make customization, modifications, and experimentation possible.
- Assemblies are open and contain more degrees of freedom than monolithic, turn-key systems to allow interoperability with many different key components (lenses, scan systems, etc.) while using well-stocked, commercially available parts, where possible.
Application:
- High-resolution imaging in neurobiology, embryology, and other areas with highly scattering tissues.
- Imaging in highly opaque tissues such as skin.
Opportunity:
For the most recent updates, improving cost and usability, please refer to MIMMS 2.0 (2018).
Open-source documentation is available for commercial and non-commercial use via the link to Flintbox at the right.
For inquiries, please reference:
Janelia 2011-006